Difference between revisions of "Add expression values (analysis)"
From BioUML platform
(Class name added) |
(Automatic synchronization with BioUML) |
||
Line 43: | Line 43: | ||
*** '''** cutoff''' – If value below this cutoff, two stars are displayed | *** '''** cutoff''' – If value below this cutoff, two stars are displayed | ||
*** '''*** cutoff''' – If value below this cutoff, three stars are displayed | *** '''*** cutoff''' – If value below this cutoff, three stars are displayed | ||
+ | ** '''Use flux edges''' – When checked, a reaction edges thickness will be changed based on reaction speed data | ||
+ | ** '''Flux options''' – Flux options | ||
+ | *** '''Column''' – Column to create inside fill | ||
+ | *** '''Minimum value''' – Lowest value in the selected columns | ||
+ | *** '''Maximum value''' – Highest value in the selected columns | ||
+ | *** '''Maximum stroke width''' – Maximum stroke width | ||
* '''Output diagram''' – Output diagram | * '''Output diagram''' – Output diagram | ||
Revision as of 19:01, 13 February 2017
- Analysis title
- Add expression values
- Provider
- Institute of Systems Biology
- Class
ExpressionFilterAnalysis
- Plugin
- biouml.plugins.expression (Expression display for diagrams)
Description
This analysis allows you to display expression values as molecules background on the specified diagram.
Parameters:
- Input diagram – Input diagram
- Mapping properties – Mapping properties
- Table – Table to use expression values from
- Use outside fill – When checked, outside fill will be used
- Outside filling options – Outside filling options
- Columns – List of columns to create outside fill
- Width of the fill – Range from 1 to 40
- Minimum value – Lowest value in the selected columns
- Start-color – Color for minimum value
- Maximum value – Highest value in the selected columns
- End-color – Color for maximum value
- Use color for zero – If checked, zero-color will be used to represent zero value
- Zero color – Color to represent zero value. Used only if minimum value 0, maximum value > 0 and 'Use color for zero' is checked.
- Zero level – Value at which zero color will be used
- Use inside fill – When checked, inside fill will be used
- Inside filling options – Inside filling options
- Column – Column to create inside fill
- Minimum value – Lowest value in the selected columns
- Start-color – Color for minimum value
- Maximum value – Highest value in the selected columns
- End-color – Color for maximum value
- Use color for zero – If checked, zero-color will be used to represent zero value
- Zero color – Color to represent zero value. Used only if minimum value 0, maximum value > 0 and 'Use color for zero' is checked.
- Zero level – Value at which zero color will be used
- Use p-value stars – When checked, a number of stars will be added to matched elements depending on p-value
- P-value stars options – *** options
- Column – Column with p-values
- * cutoff – If value below this cutoff, one star is displayed
- ** cutoff – If value below this cutoff, two stars are displayed
- *** cutoff – If value below this cutoff, three stars are displayed
- Use flux edges – When checked, a reaction edges thickness will be changed based on reaction speed data
- Flux options – Flux options
- Column – Column to create inside fill
- Minimum value – Lowest value in the selected columns
- Maximum value – Highest value in the selected columns
- Maximum stroke width – Maximum stroke width
- Output diagram – Output diagram